HMMWV · TM 9-2320-280-10

DURING OPERATIONS PMCS

Monitor these items while the vehicle is operating. Stop immediately if any NFMC condition is observed.

6 check items6 NFMC items
HMMWV #1 — During Operations

Enter your info first. Green OK, red NFMC. Print when done.

DURING OPERATIONS PROGRESS
0 / 6
TM #17NFMC

Monitor engine temperature gauge — must stay in normal operating range (between L and H)

TM #18NFMC

Monitor oil pressure gauge — must show pressure within 10 seconds of startup; minimum 10 PSI at idle

TM #19NFMC

Monitor voltmeter/ammeter — must show charge (14–15V); investigate if showing discharge

TM #20NFMC

Check for unusual engine noises — knocking, rattling, or excessive exhaust smoke

TM #21NFMC

Check steering response — no excessive play, pulling, or binding

TM #22NFMC

Check brake performance — vehicle must stop in a straight line without pulling or grinding

NFMC — No Further Movement Criteria. Any fault on an NFMC item means the vehicle is non-mission-capable and must not be dispatched until repaired. Annotate on DA Form 5988 immediately.